Abstract

In order to find out the dynamic characteristics of a steel frame structure project in the 8 degree (0.3g) area, the artificial wave, Taft wave and El Centro wave were input by using the finite element analysis software ANSYS. The dynamic time-history analysis of the structure shows the dynamic performance of the structure under the frequent earthquakes and rare earthquakes.

Keywords:

Steel frame structure, Dynamic time-history analysis, Dynamic performance